基于Ventsim的深井线性热源对有效通风量的影响分析
王从陆,李童

Analysis of Influence of Deep Mine’s Linear Heat Source on Effective Ventilation Based on Ventsim Software
Conglu WANG,Tong LI
表1 用于深井线性热源与有效通风量研究的特征分支
Table 1 Characteristic branch for the study of linear heat source and effective ventilation in deep shaft
巷道序号分支描述长度/m
1回风井,-965.0~918.6 m46.4
2回风井,-918.6~-876.1 m42.5
3回风井,-876.1~-845.0 m31.1
4回风井,-845.0~-812.3 m,连有-845 m有轨水平巷道32.7
5回风井,-812.3~-785.0 m27.3
6回风井,-785.0~-751.8 m,连有-785 m有轨水平巷道33.2
7回风井,-751.8~-725.0 m26.8
8回风井,-725.0~695.5 m29.5
9有轨水平巷道,-965.0 m57.7
10有轨水平巷道,-965.5~-966.2 m48.6
11有轨水平巷道,-965.0 m41.5
12水平掘进巷道,-645 m39.3
13水平掘进巷道,-645 m40.4
14水平掘进巷道,-645 m45.7
15水平掘进巷道,-623 m63.5