基于Ventsim的深井线性热源对有效通风量的影响分析
王从陆,李童

Analysis of Influence of Deep Mine’s Linear Heat Source on Effective Ventilation Based on Ventsim Software
Conglu WANG,Tong LI
表2 具有温差梯度的线性热源对风量的影响
Table 2 Influence of linear heat source with temperature gradient on ventilation
巷道序号A组线性热源/(W·m-1风量平均/(m3·s-1平均干球温度/压力增减/PaB组线性热源/(W·m-1平均风量/(m3·s-1平均干球温度/压力增减/Pa
11 00029.736.6-1.21 00029.536.5-1.0
2

1 000

2 000

30.537.6-1.01 50029.937.4-1.2
330.738.3-1.42 00030.338.7-0.7
4

2 000

3 000

31.840.1-0.72 50031.939.8-0.7
532.042.1-1.03 00032.441.6-0.8
6

3 000

4 000

98.737.7-10.73 50099.037.5-10.7
799.038.3-6.34 00099.838.0-6.3
899.338.4-7.0100.138.1-7.0
929.336.0-13.529.336.0-13.5
1016.336.6-3.616.336.6-3.6
1113.036.7-2.013.036.7-2.0